| ZENITH ZBTS BYPASS
ISOLATION SERIES AUTOMATIC TRANSFER SWITCH |
|
Description
In critical
applications such as hospitals and airports, power cannot be
interrupted for maintenance of automatic transfer switches. In
such circumstances, a bypass-isolation switch is essential and
is often required by code.
GE Zenith Controls ZBTS
Series Bypass-Isolation Transfer Switches are the solution
when interruption of power during service or testing is not
acceptable.
Consisting of two major
modules-the Automatic Transfer and the Bypass-Isolation
Switch-the ZBTS Series incorporates the rugged construction of
all our ZTS Series switches with a quick make/quick break
manual load transfer handle and our control/interlock system,
which consists of both mechanical and electrical interlocks.
The bypass uses normal
failure sensing and a time delay to start the engine
automatically if a failure occurs when the ATS has been
removed for service-which can be done without disturbing the
load.
Features and Benefits
 |
Load is not
interrupted during bypass operation
|
 |
High close-in and
withstand capacity
|
 |
Temperature rise
test per UL 1008 conducted after overload and endurance
tests in unventilated enclosure-exceeds UL requirements
|
 |
Available in ZBTS
(utility-generator), ZBTSU (utility-utility), ZBTSG
(generator-generator) and ZBTSM (manual) configurations;
models include standard, delayed and closed transition
|
 |
Transfer switch is
located on a draw-out mechanism to facilitate maintenance
|
 |
Emergency power
systems can be electrically tested without disturbing the
load
|
 |
Power cables do not
have to be disconnected to remove transfer switch
|
 |
Bypass to any
available source with ATS removed
|
 |
Engine start
circuit maintained during bypass operation; normal power
failure causes engine start contact closure even with the
ATS removed
|
 |
Diagnostic lights
and detailed instructions for simple step-by-step
operation
|
 |
Mechanical and
electrical interlocks ensure proper sequence of operation
|
 |
Bypass switch
contacts are closed only during the bypass-isolation
operation
|
 |
Silverplated copper
bus interconnection of the transfer and bypass switches on
all sizes
|
Product Scope
 |
Ratings 100 to 4000
amperes
|
 |
2, 3 or 4 poles
|
 |
Open type, NEMA 1,
3R, 4, 4X and 12
|
 |
Available with ZTS,
ZTSD and ZTSCT Series Transfer Switch
|
 |
Bypass and transfer
switch have identical ratings
|
 |
Suitable for
emergency and standby applications on all classes of load,
100% tungsten rated through 400 amps
|
 |
UL 1008 listed at
480 VAC
|
 |
CSA C22.2 No. 178
certified at 600 VAC
|
 |
IEC 947-6-1 listed
at 480 VAC
|
|
|

|