ZENITH ZBTS BYPASS ISOLATION SERIES AUTOMATIC TRANSFER SWITCH

Description

In critical applications such as hospitals and airports, power cannot be interrupted for maintenance of automatic transfer switches. In such circumstances, a bypass-isolation switch is essential and is often required by code.

GE Zenith Controls ZBTS Series Bypass-Isolation Transfer Switches are the solution when interruption of power during service or testing is not acceptable.

Consisting of two major modules-the Automatic Transfer and the Bypass-Isolation Switch-the ZBTS Series incorporates the rugged construction of all our ZTS Series switches with a quick make/quick break manual load transfer handle and our control/interlock system, which consists of both mechanical and electrical interlocks.

The bypass uses normal failure sensing and a time delay to start the engine automatically if a failure occurs when the ATS has been removed for service-which can be done without disturbing the load.

(Download Brochure)     

Features and Benefits

bullet
Load is not interrupted during bypass operation
bullet
High close-in and withstand capacity
bullet
Temperature rise test per UL 1008 conducted after overload and endurance tests in unventilated enclosure-exceeds UL requirements
bullet
Available in ZBTS (utility-generator), ZBTSU (utility-utility), ZBTSG (generator-generator) and ZBTSM (manual) configurations; models include standard, delayed and closed transition 
bullet
Transfer switch is located on a draw-out mechanism to facilitate maintenance 
bullet
Emergency power systems can be electrically tested without disturbing the load 
bullet
Power cables do not have to be disconnected to remove transfer switch 
bullet
Bypass to any available source with ATS removed 
bullet
Engine start circuit maintained during bypass operation; normal power failure causes engine start contact closure even with the ATS removed 
bullet
Diagnostic lights and detailed instructions for simple step-by-step operation 
bullet
Mechanical and electrical interlocks ensure proper sequence of operation 
bullet
Bypass switch contacts are closed only during the bypass-isolation operation 
bullet
Silverplated copper bus interconnection of the transfer and bypass switches on all sizes 

Product Scope

bullet
Ratings 100 to 4000 amperes 
bullet
2, 3 or 4 poles 
bullet
Open type, NEMA 1, 3R, 4, 4X and 12 
bullet
Available with ZTS, ZTSD and ZTSCT Series Transfer Switch 
bullet
Bypass and transfer switch have identical ratings 
bullet
Suitable for emergency and standby applications on all classes of load, 100% tungsten rated through 400 amps 
bullet
UL 1008 listed at 480 VAC 
bullet
CSA C22.2 No. 178 certified at 600 VAC 
bullet
IEC 947-6-1 listed at 480 VAC